When your inspection is done, your GPS1 report is in hand, and the GPS2 Certification is filed with the DOB, you’re no longer carrying a $5,000 violation on a building you’ve worked hard to maintain. That’s the real outcome — not a certificate on the wall, but a concrete risk removed from your property record.
For Tompkinsville landlords specifically, that matters more than it might in other neighborhoods. More than half of this neighborhood’s residents are renters. If a Class 1 gas deficiency forces Con Edison to shut off service, it’s not just your problem — it’s six families without cooking gas in January, and a Housing Court complaint isn’t far behind. Getting inspected on your schedule, before something forces the issue, is how you stay in control of that situation.
There’s also something worth saying about the building stock here. The majority of residential properties on and around Bay Street and Victory Boulevard were built before 1940. That’s decades of gas infrastructure that’s never had a licensed master plumber put eyes on it under LL152. Combine that with Tompkinsville’s waterfront position on Upper New York Bay — where salt air and humidity accelerate pipe corrosion year-round — and you have exactly the conditions this law was designed to address. An inspection doesn’t just keep you off a violation list. It tells you what’s actually going on inside your boiler room.
We’ve been working in New York City’s pre-war building stock since 1983. That’s not a marketing number — it’s the reason we understand what aging gas infrastructure actually looks like in a five-story walkup from 1912, because we’ve been inside hundreds of them.
We’re Manhattan-based, and Tompkinsville is a direct shot from lower Manhattan via the Staten Island Ferry into St. George — the same route your neighbors take to work every morning. The pre-war multifamily buildings along Bay Street and Victory Boulevard are the same era and construction type as the Manhattan buildings we’ve been servicing for four decades. That experience transfers directly.
What you’re getting when you call is Bobby or Rob on-site — not a subcontractor, not a crew dispatched by a franchise. The licensed master plumber whose name goes on the GPS1 report is the same person who walked your building. That matters when you’re signing off on a legal compliance document.
The process starts with scheduling. Given that Staten Island Community District 1’s Cycle 2 deadline passed on December 31, 2024, the priority right now is moving quickly. The DOB began issuing Notices of Deficiency to non-compliant SI CD1 buildings in January 2025, and formal Notices of Violation followed in January 2026. If you haven’t completed your inspection yet, you’re already in the window where enforcement is active — not theoretical.
Once you’re scheduled, the inspection itself covers all exposed gas piping from the point where gas enters your building through the common areas, boiler room, mechanical spaces, and hallways — up to but not including individual tenant units. For older Tompkinsville buildings near the waterfront, the inspection pays particular attention to atmospheric corrosion, which salt air and humidity accelerate significantly. If corrosion has reached Level 3 or 4 severity, pipe replacement is required by law — and it’s far better to find that during a scheduled inspection than during a Con Edison emergency response.
After the inspection, you receive the GPS1 report within 30 days. From there, the GPS2 Certification needs to be filed with the DOB within 60 days — and as of early 2026, that filing goes through DOB NOW only, no paper submissions. We walk you through that process so the certification gets filed correctly and your compliance gap closes. If repairs are needed, we handle them as part of the same engagement — no second vendor, no second scramble.
Ready to get started?
Local Law 152 requires a licensed master plumber to visually inspect all exposed gas piping in the common areas of your building, document any Abnormal Operating Conditions, and deliver a signed GPS1 report. That report then triggers your obligation — as the building owner — to file the GPS2 Certification with the NYC DOB. We handle both sides of that equation.
Where most inspection-only firms hand you a report and walk away, we stay in the picture. If the inspection surfaces a deficiency — a corroded section of pipe, an unsupported run, a legacy installation that doesn’t meet current code — repairs happen through the same engagement. For Tompkinsville’s older building stock, this matters. Pre-war buildings on the North Shore regularly turn up findings that a newer building wouldn’t: aging threaded pipe, boiler room infrastructure that hasn’t been touched in decades, and corrosion patterns consistent with long-term coastal humidity exposure.
It’s also worth knowing that even buildings with no gas piping have a filing obligation under LL152 — a certification confirming the absence of gas service still needs to go to the DOB. And for buildings that missed the December 31, 2024 deadline for Staten Island CD1, new 2026 DOB filing fees now apply: $35 per GPS2 Certification filing, and $480 per BIN for no-gas documentation. Getting this resolved now costs less than letting it sit.
Yes — and this is the most important thing to understand if you own a building in Tompkinsville. The neighborhood falls within Staten Island Community District 1, and the Cycle 2 Local Law 152 inspection deadline for that district was December 31, 2024. That date has passed.
If your building hasn’t completed its inspection and filed the GPS2 Certification with the NYC DOB, you are currently out of compliance. The DOB began issuing Notices of Deficiency to non-compliant SI CD1 buildings starting in January 2025. Formal Notices of Violation began going out in January 2026. The civil penalty for non-compliance is $5,000 per violation. The right move at this point isn’t to wait for the next cycle — it’s to get the inspection done, address any findings, and file the GPS2 Certification as quickly as possible to close the exposure window.
The inspection covers all exposed gas piping from the point where the gas service enters your building, through the boiler room, mechanical spaces, hallways, and other common areas — up to but not including the individual tenant apartments. In-unit piping is not part of the LL152 scope.
What we’re looking for includes visual signs of atmospheric corrosion (which is rated on a severity scale — Level 3 or 4 requires mandatory pipe replacement), improper pipe supports, gas leaks, illegal connections, and any other Abnormal Operating Conditions. For older Tompkinsville buildings along the Bay Street waterfront corridor, salt air and coastal humidity are documented accelerants of pipe corrosion, so this part of the inspection tends to be particularly relevant. After the inspection, you receive a GPS1 report documenting all findings. If deficiencies are found, you have a defined window to correct them before the DOB escalates enforcement.
Not every finding triggers a gas shutoff — and this is where a lot of building owners have unnecessary anxiety going into the inspection. Deficiencies are classified as either Class 1 or Class 2. Class 1 conditions are immediate hazards — active gas leaks, for example — and those do require the utility to be notified and gas to be shut off until the repair is made. Class 2 conditions are serious but not immediately dangerous, and they typically allow the gas to remain on while corrections are completed within a set timeframe.
For most older Tompkinsville buildings, the findings tend to be things like corroded pipe sections, missing or damaged supports, or legacy installations that predate current code. These are fixable. What matters is having a plumber who can make those repairs immediately rather than requiring you to source a second contractor under deadline pressure. We handle both the inspection and any repairs, so if something is found, it gets addressed in the same engagement — not after a separate bidding process.
The inspection must be performed by a Licensed Master Plumber, or by a Registered Journeyman Plumber working under the direct supervision of a Licensed Master Plumber who has completed the DOB’s required 7-hour Periodic Gas Piping Inspector Qualification course. This is not a flexible requirement — if the person who conducts your inspection doesn’t hold the right credential, the GPS1 report they produce won’t be accepted by the DOB, and your building remains out of compliance regardless of what was inspected.
The DOB explicitly encourages building owners to verify an LMP’s license status and disciplinary record before hiring. You can do this through the DOB’s public database. Our licensed master plumbers — Bobby and Rob — hold current LMP credentials and have been actively licensed in New York City since 1983. That’s not a claim you can verify with a newer firm or a franchise operation that staffs out subcontractors.
The GPS2 is the Gas Piping System Periodic Inspection Certification — it’s the document that the building owner (not the plumber) is legally required to file with the NYC DOB after the inspection is complete. The licensed master plumber produces the GPS1 report; the GPS2 filing is your obligation as the property owner.
You have 60 days from the date of the inspection to file the GPS2. As of early 2026, all GPS2 filings must go through DOB NOW — the city’s digital portal. Paper submissions are no longer accepted. For Tompkinsville building owners who went through the first LL152 cycle in 2020 using a different process, or who are filing for the first time after missing the December 2024 deadline, the DOB NOW system may be unfamiliar. New filing fees also apply in 2026: $35 per GPS2 Certification filing. We walk you through the GPS2 submission process so it gets filed correctly and doesn’t generate a procedural rejection that extends your non-compliance window.
It’s a reasonable concern, especially given that most of Tompkinsville’s residential buildings were constructed before 1940. But the honest answer is that knowing what’s there is always better than not knowing. A deficiency found during a scheduled LL152 inspection is something you can address on your own timeline, with a plumber you chose, at a cost you can plan for. A deficiency found during a Con Edison emergency response — or triggered by a tenant complaint — is a completely different situation, and far more disruptive and expensive.
The inspection itself is a visual survey of exposed piping. It’s not a full system teardown. Most older buildings pass with minor findings or none at all. The ones that do have issues — corroded sections, aging supports, legacy work that doesn’t meet current code — are exactly the buildings where finding it early matters most. For Tompkinsville’s waterfront buildings near Bay Street, where salt air and humidity have been working on that piping for decades, the inspection gives you a clear picture of where things actually stand. That’s information worth having, regardless of what it shows.